Samsung FJM R32 outdoor unit from 4kW to 10kW

€2,258.30
Tax included
AJ040TXJ2KG/EU
0768563817915

Samsung outdoor units:


AJ040TXJ2KG/EU
AJ050TXJ2KG/EU
AJ052TXJ3KG/EU
AJ068TXJ3KG/EU
AJ080TXJ4KG/EU
AJ100TXJ5KG/EU

Samsung Outdoor Unit: AJ040TXJ2KG/EU

Sorry, there are no more items in stock.

Samsung FJM R32 outdoor...

€2,258.30

One outdoor unit, several indoor units

 

When you want to heat or cool multiple spaces, Samsung's Free Joint Multi system offers you the perfect solution. With a single outdoor unit and up to 5 interior units, this ultra-silent system easily creates a perfect indoor climate. You also have a lot of freedom to choose models and abilities.
Its modulating capacity regulation makes the Free Joint Multi an extremely economical system.


Flexibility


Samsung's compact Free Joint Multi system offers you the perfect solution when you want to heat or cool multiple rooms, such as your living room and bedroom, or a closet, waiting room or office.
Depending on the occupancy in the different rooms, you can turn on the number of interior units you want. The modulating capacity regulation allocates proportionally the available capacity between the activated units.
The big advantage is that you only heat or cool the parts you use. An energy-efficient solution!


Your benefits in a nutshell

 

Heating, cooling and dehumiding with a single system
Up to a maximum of 5 indoor units for an outdoor unit
Freedom of choice of the type of inner unit
Heating very low energy and fast
Capacity regulation, up to 170% simultaneous


Optimal comfort all year round


Samsung's Free Joint Multi system, equipped with a heat pump, can heat and cool the room very quickly, using little energy. Therefore, with a Samsung heat pump, you can enjoy a pleasant indoor temperature in all seasons, while making considerable savings on your energy bill!


Fast heating


The big advantage of heating with an air heat pump is that the desired temperature is quickly reached. Indeed, the hot air blown into the room ensures a quick and comfortable heating. When the system is turned off, the residual heat is virtually zero and the room cools relatively quickly.
This is the ideal system for a room for example, where locals want to study warm but sleep in a cool place. Get advice from your installer to find out what's the best solution for your situation.


Several models of interior units


With the Free Joint Multi system, you can choose from several interior units. Placed high on the wall, the wall models are ideal when there is no false ceiling. Thanks to their stylish design, the units offer an added valuer to each interior. If the wall installation is not desirable or possible, the recessed models can be used.
For example, cassette models are embedded in the ceiling, where only the aesthetic panels remain visible. The sheathable models are fully integrated into a (false) ceiling and offer optimal comfort. The console model is placed on the ground against the wall. Discover the possibilities of Samsung's Free Joint Multi system!


Air dehumidification


Besides a pleasant temperature, the humidity of the air is also a very important factor for our comfort.
Our body regulates its own temperature by releasing moisture. If the air around us is saturated and can no longer absorb this moisture, we have heat release problems and feel the sensation
unpleasant to stick and suffocate. A Samsung heat pump not only heats and cools, but also dehumidifies the air during cooling.

 

Samsung Wind-Free™: a cooling without draft


Wind-Free™ is the revolutionary new way to cool without air current. Thanks to the thousands of microperforations in the box, the air is blown at low speed.
Samsung Wind-Free™ is available in combination with a Free Joint Multi system for the wall model, the 1-way cassette and the 4-way mini-cassette.


Silent operation of the external unit


The interior units of the Free Joint Multi, equipped with a Twin BLDC compressor, are extremely quiet.
The FJM compressor is covered with two layers of acoustic insulation that absorbs and reduces noise.


 Technical data

 

ModelAJ040TXJ2KG/EUAJ050TXJ2KG/EUAJ052TXJ3KG/EUAJ068TXJ3KG/EUAJ080TXJ4KG/EUAJ100TXJ5KG/EU
Ability
Ability Cooling (nominal)Kw4.05.05.26.88.010.0
Heating up -7 degrees CelsiusKw4.25.66.38.09.312.0
Heating up --5CKw3.164.224.226.027.009.03
Heating - 10 degrees CelsiusKw2.703.603.605.145.977.70
Heating - 15 degrees CelsiusKw2.232.982.984.254.946.38
Performance
Energy efficiency of coolingSEERW/W8.548.548.517.757.758.00
Energy consumptionkWh/a164205206293330-
Declared refrigeration chargeKw4.05.05.06.57.3-
EraW/W4.444.104.163.784.063.64
Energy efficiency of heatingScopW/W4.604.644.604.324.104.32
Energy consumptionkWh/a9221,2701,4001,8332,009-
Declared calorific charge (average)Kw3.14.224.605.75.9-
CopW/W4.644.384.774.424.374.26
Air flowm3/min29.733.138.047.547.575.0
Acoustic powerdB(A)606161646470
Acoussitque pressureCoolingdB(A)454646484854
HeatingdB(A)464748505056
FanTypeHelicalHelicalHelicalHelicalHelicalHelical
Winding directionFront (horizontal)Front (horizontal)Front (horizontal)Front (horizontal)Front (horizontal)Front (horizontal)
PowerW4040125125125125
Number of fans-111111
Operating rangeCooling-5.0-46.0-5.0-46.0-10.0-46.0-10.0-46.0-10.0-46.0-10.0-46.0
Heating-15-24-15-24-15-24-15-24-15-24-15-24
Installation data
VoltageΦ, V, Hz1,220-240V, 50Hz1,220-240V, 50Hz1,220-240V, 50Hz1,220-240V, 50Hz1,220-240V, 50Hz1,220-240V, 50Hz
Type of compressorTwin BLDC RotaryTwin BLDC RotaryTwin BLDC RotaryTwin BLDC RotaryTwin BLDC RotaryTwin BLDC Rotary
Energy consumptionCoolingKw0.901.221.251.801.972.75
HeatingKw0.901.281.321.812.132.82
Nominal currentCoolingHas4.15.65.58.18.912.2
HeatingHas4.15.96.18.29.512.8
Size
Size (LxHxP)Mr790x548x285790x548x285880x638x310880x798x310880x798x310940x998x330
WeightKg32.033.044.557.557.576.5
Refrigerant
RefrigerantType       
Pre-fillingKg0.981.181.552.002.02.70
Max length with pre-fillingMr30.030.030.030.040.040.0
Co2 pre-filling, equivalenttCO2e0.660.801.051.351.351.82
Refrigerant refillg/m--10102010
Connecting the pipingLiquidThumb1/4x21/4x21/4x214x3144 
GasThumb3/8x23/8x23/8x2-1/23/8-1/2x23/8x2-1/2x23/8x2-1/2x3
Length of drivingTotal length of pipingMr303050507075
Min/Max - per unit int.Mr3/253/253/253/253/253/25
Length of drivingMax height (UI-UI)Mr7.57.57.57.57.57.5
Max height (EU-UI)Mr151515151515
AJ040TXJ2KG/EU
-2 Items

Data sheet

Width
880 mm
Height
793 mm
Thickness
310 mm
Weight
62 kg

Specific References

UPC
768563817915
EAN13
0768563817915
New