Sofar Solar 6 kVA single-phase hybrid inverter - HYD6000-EP
Single-phase hybrid inverter - the perfect solution to enable energy storage in your PV installation with on-grid and off-grid functions.
The HYD 3000...6000-EP is the new multi-talented hybrid inverter for solar and storage applications. During grid failures, it can provide up to 5 kW of emergency power supply (EPS) in 10 ms thanks to its integrated EPS port. The integrated energy management system features several user-friendly modes, optimizing the user experience, including an automatic self-use mode. Users can also define different time and/or date ranges, or rules for the day of the week. All modes can be easily configured on the large LCD display.
A WiFi key is supplied with the inverter, for easy connection to the Sofar monitoring portal.
High efficiency
- Maximum efficiency of 99.9%. - Precise real-time MPPT algorithm for maximum utilization - Wide input voltage operating range
Flexible configuration
The inverter works with lead (GEL) or lithium batteries.
Use in back-up mode
An inverter can be used in "back-up" mode, without the need for photovoltaic panels. In this mode, the UPS assumes the role of an inverter to protect your equipment from grid interruptions. As a result, an inverter protects computers and audiovisual equipment, or any other sensitive load, by providing a constant flow of electrical current. It guarantees a power supply with a switchover time of less than 10 ms, thanks to the EPS function.
Hybrid mode operation
The inverter draws power from the grid only when the battery is depleted and solar energy is not producing enough to meet consumption.
All in one. Flexible, cost-effective system solution
- Free choice of location thanks to IP65 rating - Plug & Play" connection for easy installation and maintenance - Interface selection - Wi-Fi / RS485 /GPRS - LCD + LED display - Integrated zero export function
Low maintenance costs
- Detachable lid for easy installation - Stainless aluminum covers - A flexible control solution
Standard display
The display shows all relevant inverter information.
Wiring and connection
BATTERY - Battery + and - input terminals
OFF / ON - DC switch
PV 1 & PV 2 - Solar inputs (male and female)
WIFI
- GPRS - USB key connection - Wi-Fi
COM - Communication port
Link Port 0 &
1 - 0 & 1 link port
Grid connection port
Load connection port
External LCD Terminal - External LCD connection port
Hybrid Inverters: Operating modes
Self-use mode
If PV production matches consumption, the inverter neither charges nor discharges the battery.
If PV production exceeds consumption, surplus energy is stored in the battery.
If the battery is full or at maximum charging capacity, surplus energy is exported to the grid.
If PV production is lower than consumption, the battery is discharged to supply energy to loads.
If user energy consumption exceeds PV production, and battery capacity is unable to compensate, the inverter will import energy from the grid.
Supply priority: PV > Battery > Grid
Consumption priority: Loads > Battery > Grid
Time-of-Use Mode:
The user can define up to four rules on when the battery should be charged.
Each rule can be activated or deactivated and includes time of day, percentage of battery charge (SOC), charging power, efficiency date and days of the week.
Timing Mode.
The user can define fixed times of the day to charge or discharge the battery with a given power.
Up to four rules can be defined, and each rule can be activated or deactivated separately for charging or discharging.
Passive Mode.
Intended for systems with external energy management systems using the Modbus RTU protocol to control the inverter.
If the battery is fully charged or at its maximum charging power, PV production is reduced by adjusting the maximum power point (MPPT).
If PV production is lower than consumption, the battery supplies the loads.
EPS Mode (EPS Mode).
When this mode is activated, the inverter supplies energy to loads when it is off-grid, for example when there is no connection to the public grid or during power failures.
If PV production exceeds consumption, the surplus is stored in the battery.
These modes allow the user to flexibly manage how energy is stored and used, optimizing the use of batteries and solar power generation.
Retro-Fit
Optimization of an existing grid-connected installation
SolarMan Smart
SofarSolar redefines the future of energy with smart inverters. Equipped with advanced monitoring features, our inverters include WiFi Stick as standard, paving the way for seamless connectivity. Choose your path to efficiency with options such as Ethernet, GPRS or LTE keys. Transform every installation into a digital symphony, where solar power becomes a connected, intelligent and sustainable experience. SofarSolar, your partner for smarter, brighter energy.
1. After starting the application, register as a new user or enter your current SOLARMAN access data. 2. Create a new system and save the system data. 3. Scan the stick logger barcode to assign an inverter to the system. 4. Access the newly created system to configure the stick logger (device/logger). 5. Press the WiFi stick button for 1 second to activate the stick's WPS mode so that the smartphone can be connected to the WiFi stick. 6. Now select your local WiFi network for Internet access and enter your WiFi password. 7. The WiFi key is configured with access data.
5-year warranty for reliable energy
Dive into the energy future with confidence with Sofar Solar hybrid inverters, because we guarantee the outstanding performance of our products for 5 years. A symbol of our commitment to quality, this warranty offers the peace of mind you need to fully embrace the potential of hybrid energy, transforming your everyday life into a reliable and sustainable energy experience.
Features
Battery parameters
Battery type
Lithium-ion,
Lead-acid
Nominal battery voltage
48 V
Battery voltage range
42 - 58 V
Battery capacity
50 - 2000 Ah
Max. charging/discharging power
5000 W
Max. charging current.
100
A
Max. discharge current
100
A
BMS
Charging curve (lithium-ion)
(Battery Management System)
Charging curve (lead-acid)
3-level adaptive with maintenance
ion
Depth of discharge
Lithium
: 0 - 90% DOD adjustable, lead acid:
0 - 50% DOD adjustable (depth of charge)
DC input (PV side)
9000
Recommended maximum PV input power
Wp
Maximum DC power for a single MPPT
3750 W
Maximum input voltage
600 V
V
Starting voltage
100
V
Nominal input voltage
360 V
MPPT operating voltage range
90 - 550 V
MPPT voltage range at full power
300 - 500 V
2
Number of MPP trackers
Maximum input current per MPPT
13 / 13 A
Short-circuit currentcircuit per MPPT
18 / 18 A
AC output / input (grid side)
Rated AC power
6000 W
Max AC output power to grid
6000 VA
Max AC
output
power to grid
12000 VA
Max AC output current to grid
27,3 A
Max. AC current.
from mains
54.6 A
L
Nominal mains voltage
/ N / PE, 230 Vac
)
Mains voltage range
180 Vac-276 Vac (depending on local standard
Nominal frequency
50 Hz / 60 Hz
Output THDi (at nominal output)
<
3%
1
Power factor
default (+/-0.8 adjustable)
AC output (emergency power supply)
Maximum apparent power
5000 VA
Peak output power,
duration
6000 VA, 60s
Maximum output current
22.7 A
Rated voltage, frequency
220 V / 230 V, 50 / 60 Hz
THDv (@Symmetrical load)
<
3
%
Switching time
10 ms default
Efficiency
MPPT efficiency
99,90%
Maximum solar inverter efficiency
98,00%
European solar inverter efficiency
97.50%
Maximum battery charging efficiency
94.60%
Maximum battery discharging efficiency
94,60%
Protection
PV reverse polarity protection
Yes
PV insulation detection
Yes
Ground fault monitoring
Yes
Overcurrent protectionprotection
overcurrent
Yes
Overvoltage protection
Yes
DC switch
Optional
Firm frequency response function
Optional
SDP protection
Varistor:
Type III standard
General data
-30℃~+60℃
Ambient temperature range
(over 45℃ derating)
Standby power consumption
<
10 W
Topology
High-frequency insulation (for battery)
protection
Degree of
IP65
0~100%
Permissible humidity range
Communication
RS485 / WiFi / Bluetooth / CAN2.0 / Etherrnet
Protection class
Class I
Maximum operating altitude
4000 m
Current sensor connection
External
Noise
<25 dB
Weight (kg)
21.5 kg
Cooling
Natural
Dimensions
482 x 503 x 183 mm
Display
LCD,
App via Bluetooth
5
Warranty
years
Certifications and standards
EMC
EN 61000-6-2, EN 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11,