![](https://www.wattuneed.com/42381-large_default/three-phase-inverter-sma-sunny-tripower-stp-4-kva-tl-stp40-3av-40.jpg)
![](https://www.wattuneed.com/42382-large_default/three-phase-inverter-sma-sunny-tripower-stp-4-kva-tl-stp40-3av-40.jpg)
![](https://www.wattuneed.com/42380-large_default/three-phase-inverter-sma-sunny-tripower-stp-4-kva-tl-stp40-3av-40.jpg)
![](https://www.wattuneed.com/42381-slider_photo/three-phase-inverter-sma-sunny-tripower-stp-4-kva-tl-stp40-3av-40.jpg)
![](https://www.wattuneed.com/42382-slider_photo/three-phase-inverter-sma-sunny-tripower-stp-4-kva-tl-stp40-3av-40.jpg)
![](https://www.wattuneed.com/42380-slider_photo/three-phase-inverter-sma-sunny-tripower-stp-4-kva-tl-stp40-3av-40.jpg)
SMA Sunny Tripower three-phase inverter - model: 4.0TL
This inverter is ideal for both traditional residential photovoltaic installations and much more powerful systems.
Economical
Flexible
Interactive
Simple
.0
Technical data | Sunny Tripower 3 | Sunny Tripower 4.0 | Sunny Tripower 5.0 | Sunny Tripower 6.0 |
800090009000
Input (DC) | 6000 Wp |
Wp | |
Wp | |
Wp |
Max. power of photovoltaic generator | 850 V |
Max. input voltage | 140 | ||
V to 800 V | 175 V to 800 V | 215 V to 800 V | 260 V to 800 V |
580
MPP voltage range | |||
V |
Rated input voltage | 125 V / 150 V |
Input voltage min. | ||||
/ start-up input voltage Max. input current input A / input B | 12 A / 12 A |
Max. short-circuit current. | ||||
input A / input B | 18 A / 18 A |
2
Number of independent MPP inputs / strings per MPP input Output (AC) | |||
/ A:1; B:1 |
Rated power (at 230 V, 50 Hz) | 3000 W | 4000 W | 5000 W | 6000 W |
Max. apparent AC power | 3000 | ||
VA | 4000 VA | 5000 VA | 6000 VA |
3/N/PE
Rated AC voltage | |||
; 220 V / 380 V 3/N/PE; 230 V / 400 V 3/N/PE; | |||
240 V / 415 V |
AC voltage range | 180 V to 280 V |
AC mains frequency / Range | 50 Hz / 45 Hz to 55 Hz 60 Hz to 65 Hz |
Rated mains frequency / Rated mains voltage | 50 Hz / 230 V |
333
Max. output current | 3 |
x 4.5 A | |
x 5.8 A | |
x 7.6 A | |
x 9.1 A |
1
Power factor at rated power / adjustable phase shift factor Injection phases / Connection phases | |||
/ 0.8 inductive to 0.8 capacitive |
Efficiency |
%
Max. efficiency. | / European efficiency | 98.2 % / 96.5 % | 98.2 % / 97.1 | 98.2 % / 97.4 % | 98.2 % / 97,6 % |
Protective devices |
Input-side disconnection device | ● |
Ground fault monitoring / network monitoring | ●/● |
DC reverse polarity protection / AC short-circuit resistance / galvanic separation | ●/●/- |
Fault current monitoring unit, | ||||
sensitive to all currents Protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) | ● |
I
Protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) | |||
/ III |
General features |
435
Dimensions (L/H/P) | |||
mm / 470 mm / 176 mm (17,1 inches / 18.5 inches / 6.9 inches) |
Weight | 17 kg (37.4 lb) |
Operating temperature range | -25 °C to +60 °C (-13 °F to +140 °F) |
Noise emissions, typical | 30 dB(A) |
5
Autoconsumption (night) | |||
,0 W |
Topology / Cooling system | Transformerless / Convection |
Protection class (to IEC 60529) | IP65 |
4K4H
Climatic class (to IEC 60721-3-4) |
Maximum permissible value for relative air humidity (non-condensing) Equipment | 100,00% |
Equipment |
connection
DC | ||||
/ AC connection | SUNCLIX / AC plug |
Shade management : | ||||
OptiTrac Global Peak / TS4-R | ●/○ |
Warranty : | ||||
5 / 10 / 15 years | ●/○/○ |
Certifications and approvals (others on request) | AS 4777, C10/11, CE, CEI 0-21, DIN EN 62109-1/IEC 62109-1, DIN EN 62109-2/IEC 62109-2, EN 50438, G59/3, G83/2, NEN-EN 50438, ÖVE / ÖNORM E 8001-4-712, PPDS, PPC, RD 1699, SI 4777, TR 3.2.1, UTE C15-712, VDE-AR-N 4105, VDE-0126-1-1, VFR 2014 |
Certifications and approvals (planned) | DEWA 2016, EN 62116, IEC 61727, IE-EN 50438, NBR 16149, NRS 097-2-1 |
Type designation | STP3.0-3AV-40 | STP4.0-3AV-40 | STP5.0-3AV-40 | STP6.0-3AV-40 |