keyboard_arrow_left
keyboard_arrow_right






The Sunny Tripower CORE1 is the new benchmark for inverters for large photovoltaic installations. Its innovative and self-standing design allows for up to 60% faster installation, significantly reducing costs. Ideal for rooftops, ground-mounted systems, or parking canopies, it offers unmatched flexibility and profitability.
Why choose the Sunny Tripower CORE1?
Key advantages:
SMA Sunny Tripower CORE1: The ideal solution for your large-scale solar projects.
The Sunny Tripower is the first self-supporting string inverter for photovoltaic installations on large roofs, on the ground or in parking decks, and features an innovative design. As a result, installation is up to 60% faster and costs are reduced.
The third generation of the globally successful Sunny Tripower inverter range, the Sunny Tripower CORE1 revolutionizes the inverter segment for large-roof photovoltaic installations. The Sunny Tripower combines a unique design with an innovative installation concept that considerably reduces installation time. You benefit from an optimal return on investment.
The versatile solution with optimum return on investment - from distribution to construction and operation, the Sunny Tripower CORE1 cuts logistical, material, professional and service costs.
Additional savings ...
THE ADVANTAGES FOR DISTRIBUTORS
Reduce procurement and installation costs ...
BENEFITS FOR EPCS AND DEVELOPERS
Technical data | Sunny Tripower CORE1 |
Input (DC) |
Max. power | |
photovoltaic generator | 75000 Wp STC |
Max. input voltage | 1000 V |
MPP voltage range / input voltage assigned |
500 V to 800 V / |
670 V |
/ start-up input voltage | 150 V / 188 V |
Max. input current / per MPPT | 120 A / 20 A |
Max. short-circuit current. | |
per MPP tracker/ per string input | 30 A / 30 A |
Number of independent MPPT inputs / strings per MPPT input | 06/02/19 |
Output (AC) |
Assigned power (for 230 V, | |
0 Hz) | 50000 W |
Max. apparent AC power | 50000 VA |
Nominal AC voltage | 220 V / 380 V 230 V / 400 V 240 V / 415 V |
AC voltage range | 202 to 305 V |
Frequency of the | |
AC mains frequency/range | 50 Hz / 44 Hz to 55 Hz 60 Hz / 54 Hz to 65 Hz |
Rated mains frequency/rated mains voltage | 50 Hz / 230 V |
Max. output current./Assigned output current | 72.5 A / 72.5 A |
Injection phases/AC connection |
/ 3-(N)-PE |
Power factor at rated power/ Adjustable phase shift factor |
/ 0 inductive to 0 capacitive |
THD | <3% |
Protective devices |
DC-side disconnection device | ● |
Ground fault monitoring/network monitoring | ● / ● |
DC reverse polarity protection/short-circuit resistance circuits/galvanic separation | ● / ● / - |
Fault current monitoring unit, sensitive to all currents | ● |
Protection class (to IEC 62109-1)/ overvoltage category (to 62109-1) | I/ AC: |
III; DC: II |
AC/DC surge arrester type II | ○ / ○ |
Max. efficiency./european | 98.1 % / 97.8 % |
General specifications |
Dimensions (L/H/P) |
mm / 733 mm / 569 mm (24.4 in / 28.8 in / 22.4 in) |
Weight | 84 kg (185 lb) |
Operating temperature range | -25 °C to +60 °C (-13 °F to +140 °F) |
Noise emissions (typical) | <65 dB(A) |
Autoconsumption (night) |
,8 W |
Topology/cooling system | Transformerless / OptiCool |
of protection (to IEC 60529) | IP65 |
Climatic class (to IEC 60721-3-4) |
Maximum permissible relative humidity (non-condensing) | 100,00% |
Equipment/Function/Accessories |
DC connection/AC connection | SUNCLIX/Screw terminal |
Support feet | ● |
LED display (status/error/communication) | ● |
Relays | |
multifunction/Ports for extension modules | ● / ● (2 inputs) |
OptiTrack Global Peak/Integrated Plant Control/Q on Demand 24/7 | ● / ● / ● |
Compatible off-grid/compatible SMA Fuel Save Controller | ● / ● |
Warranty : | |
5/10/15/20 years | ● / ○ / ○ / ○ |
Certifications and approvals (others on request) | |
Not valid for all national appendices of EN 50438 | ANRE 30, AS 4777, BDEW 2008, |
:2012, CE, CEI 0-16, CEI 0-21, EN 50438:2013*, G59/3, IEC 60068-2-x, IEC 61727, IEC 62109-1/2, IEC 62116, MEA 2016, NBR 16149, NEN EN 50438, NRS 097-2-1, PEA 2016, PPC, RD 1699/413, RD 661/2007, Res. n°7:2013, SI4777, TOR D4, TR 3.2.2, UTE C15-712-1, VDE 0126-1-1, VDE-ARN 4105, VFR 2014, P.O.12.3, NTCO-NTCyS, GC 8.9H, PR20, DEWA |
Standard equipment ○ Optional equipment - Not available Data at rated conditions - version: 07/2017 |
Type designation | STP 50-40 |