Victron MultiPlus-II 12/24/48 V 3000
MultiPlus-II combines the functions of MultiPlus and MultiGrid.
It features all the functions of the MultiPlus, with the option of an external current transformer to implement PowerControl and PowerAssist functions, and to optimize self-consumption with an external current probe (max. 32 A).
It also features all MultiGrid functions, with anti-islanding and a long and growing list of certifications for many countries.
Note: for some time, this product was called MultiGrid-II.
Converter / Charger MultiPlus-II
A MultiPlus with ESS (Energy Storage System) functionality
The MultiPlus-II is a multi-functional inverter/charger with all the features of the MultiPlus, plus an optional external current sensor to increase the PowerControl and PowerAssist functions to 50 A and 100 A respectively.The MultiPlus-II is ideal for professional marine installations, with sailboats, vehicles and off-grid land systems.
It is also equipped with an anti-islanding system, and has a long and growing list of certifications for many countries for ESS applications. Several system configurations are possible. For more information, consult the ESS System Design and Installation manual.
PowerControl and PowerAssist - Improving grid or generator capacity
It is possible to set a maximum current for the generator or network. The MultiPlus-II then takes account of other AC loads and will only use the excess for the load, thus avoiding any overloading of the mains or generator supply (PowerControl function).
The PowerAssist function adds an extra dimension to the PowerControl principle If a high peak power demand is often required for a short period, the MultiPlus-II will compensate for the lack of power from the generator, shore power or grid with energy from the battery. And when demand falls, the surplus power is used to recharge the batteries.
Solar power: AC power available even in the event of grid failure
The MultiPlus-II can be used both off-grid and connected to a PV grid or other alternative energy systems. It is compatible with both solar charge controllers and grid-connected converters.
Two AC outputs
The main output has an uninterrupted power supply function. In the event of grid failure or disconnection of shore power or generator power, the MultiPlus-II takes over the supply of connected loads. This transfer is so fast (less than 20 milliseconds) that the operation of connected computers or other sensitive electronic equipment will not be disrupted.
The second output is only energized when AC power is available at the MultiPlus-II input. Loads that would not discharge the battery, such as a water heater, can be connected to this output.
Power multiplied by parallel and three-phase operation (not available for 8 and 10 k models)
Up to 6 Multi units can be operated in parallel to increase output power. For example, six 48/5000/70 units will provide 25 kW / 30 kVA output power and 420 Amps load capacity.
In addition to parallel connection, three units of the same model can be configured for three-phase output. But that's not all: up to 6 series of 3 units can be connected in parallel for an inverter output of 75 kW / 90 kVA and over 1200 A of load capacity.
On-site system configuration, monitoring and control
Parameters can be changed in a matter of minutes using VEConfigure software (desktop or laptop computer and MK3-USB interface required).
Several control and monitoring options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, desktop or laptop computer, Bluetooth (with optional VE.Bus Smart dongle), battery controller, Multi Control digital control panel.
Remote configuration and supervision
Install a Color Control GX or other GX product for Internet connection.
Operating data can be stored and displayed on our free VRM (Victron Remote Management) website.
If systems are connected via Ethernet, they can be accessed and their configuration modified.
Standard marine, mobile or off-grid application
Loads that need to be switched off when AC input power is not available can be connected to a second output (not switched off). These loads will be taken into account by the
PowerControl and PowerAssist functions to limit the AC input current to a safe value if AC power is available.
Grid-parallel topology with MPPT solar charge controller
The MultiPlus-II will use data from the AC current sensor (to be ordered separately) or from the power meter to optimize self-consumption and, if necessary, avoid feeding energy back into the grid. In the event of a power failure, the MultiPlusII will continue to supply critical loads.
Features
MultiPlus-II | 12/3000/120-32 - 24/3000/70-32 - 48/3000/35-32 | 24/5000/120-50 - 48/5000/70-50 | 48/8000/110- 100 | 48/10000/140 -100 |
PowerControl / PowerAssist | Yes | |||
Transfer switch | 32 A | 50A | 100A | |
Maximum AC input current | 32 A | 50A | 100A | |
CONVERTER | ||||
DC supply voltage range | 12V - 9.5-17 V 24 V - 19-33 V 48 V - 38-66 V | |||
Output | Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0.1% (1) | |||
Continuous output power at 25°C (3) | 3000 VA | 5000 VA | VA | 10000 VA |
Continuous output power at 25°C | 2400 W | 4000 W | 6400 W | W |
Continuous output power at 40°C | 2200 W | 3700 W | 5500 W | W |
Continuous output power at 65 °C | 1700 W | 3000 W | 4000 W | 6000 W |
Assumed max. return power | 3000 VA | 5000 VA | VA | 10000 VA |
Peak power | 5500 W | W | 15000 W | 18000 W |
Maximum efficiency | 93 % / 94 % / 95 % | 96 % | 95 % | 96 % |
No-load power consumption | 13 / 13 / 11 W | 18 W | 29 W | 38 W |
No-load power consumption in AES mode | / 9 / 7 W | 12 W | 19 W | 27 W |
Zero charge power in Search mode | / 3 / 2 W | W | W | W |
CHARGER | ||||
AC input | Supply voltage range: 187-265 VAC Input frequency: 45 - 65 Hz | |||
Absorption charging voltage | 14.4 / 28.8 / 57.6 V | |||
Float charge voltage | 13.8 / 27.6 / 55.2 V | |||
Storage mode | 13.2 / 26.4 / 52.8 V | |||
Maximum battery charging current | 120 /70 / 35 A | 120 / 70 A | 110 A | 140 A |
Battery temperature sensor | Yes | |||
GENERAL | ||||
Auxiliary output | Yes (32 A) | Yes (50 A) | ||
External AC current sensor (optional) | 50 A | 100 A | ||
Programmable relay | Yes | |||
Protection | - g | |||
VE.Bus communication port | For parallel (not compatible with 8 and 10 k models) or three-phase operation, remote control and system integration | |||
Universal com. port | Yes, 2x | |||
Remote on/off | Yes | |||
Operating temperature range | to +65°C (fan cooled) | |||
Humidity (non-condensing) | max. 95 | |||
CASING | ||||
Material and color | Steel, blue RAL 5012 | |||
Degree of protection | IP22 | |||
Battery connection | M8 nuts | M8 bolts (2 positive and 2 negative connections) | ||
Connection 230 VAC | Screw terminals 13 mm2 (6 AWG) | Bolts M6 | ||
Weight | 19 kg | 30 kg | 42 kg | 49 kg |
Dimensions (H x W x D) mm | 546 x 275 x 147 499 x 268 x 141 499 x 268 x 141 | x 328 x 240 560 x 320 x 141 | 642 x 363 x 206 | x 363 x 206 |
STANDARDS | ||||
Safety | EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 | |||
Emission, Immunity | EN 55014-1, EN 55014-2 EN-IEC 61000-3-2, EN-IEC 61000-3-3 IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 |