2
    Victron MultiPlus-II 24/48 V 5000
    Victron MultiPlus-II 24/48 V 5000
    Victron MultiPlus-II 24/48 V 5000

    Victron MultiPlus-II 24/48 V 5000

    €2,642.64
    Tax included
    PMP242505010
    0768563817229

    MultiPlus-II combines the functions of MultiPlus and MultiGrid.
    It features all the functions of the MultiPlus, with the option of an external current transformer to implement PowerControl and PowerAssist functions, and to optimize self-consumption with an external current probe (max. 32 A).
    It also features all MultiGrid functions, with anti-islanding and a long and growing list of certifications for many countries.
    Note: for some time, this product was called MultiGrid-II.

    Victron Multiplus II: 24/5000/120-50

    Victron MultiPlus-II 24/48...

    €2,642.64

    Converter / Charger MultiPlus-II

    A MultiPlus with ESS (Energy Storage System) functionality

    The MultiPlus-II is a multi-functional inverter/charger with all the features of the MultiPlus, plus an optional external current sensor to increase the PowerControl and PowerAssist functions to 50 A and 100 A respectively.The MultiPlus-II is ideal for professional marine installations, with sailboats, vehicles and off-grid land systems.

    It is also equipped with an anti-islanding system, and has a long and growing list of certifications for many countries for ESS applications. Several system configurations are possible. For more information, consult the ESS System Design and Installation manual.


    PowerControl and PowerAssist - Improving grid or generator capacity

    It is possible to set a maximum current for the generator or network. The MultiPlus-II then takes account of other AC loads and will only use the excess for the load, thus avoiding any overloading of the mains or generator supply (PowerControl function).

    The PowerAssist function adds an extra dimension to the PowerControl principle If a high peak power demand is often required for a short period, the MultiPlus-II will compensate for the lack of power from the generator, shore power or grid power with energy from the battery. And when demand falls, the surplus power is used to recharge the batteries.


    Solar power: AC power available even in the event of grid failure


    The MultiPlus-II can be used both off-grid and connected to a PV grid or other alternative energy systems. It is compatible with both solar charge controllers and grid-connected converters.


    Two AC outputs


    The main output has an uninterrupted power supply function. In the event of grid failure or disconnection of shore power or generator power, the MultiPlus-II takes over the supply of connected loads. This transfer is so fast (less than 20 milliseconds) that the operation of connected computers or other sensitive electronic equipment will not be disrupted.

    The second output is only energized when AC power is available at the MultiPlus-II input. Loads that would not discharge the battery, such as a water heater, can be connected to this output.


    Power multiplied by parallel and three-phase operation (not available for 8 and 10 k models)


    Up to 6 Multi units can be operated in parallel to increase output power. For example, six 48/5000/70 units will provide 25 kW / 30 kVA output power and 420 Amps load capacity.
    In addition to parallel connection, three units of the same model can be configured for three-phase output. But that's not all: up to 6 series of 3 units can be connected in parallel for an inverter output of 75 kW / 90 kVA and over 1200 A of load capacity.


    On-site system configuration, monitoring and control


    Parameters can be changed in a matter of minutes using VEConfigure software (desktop or laptop computer and MK3-USB interface required).
    Several control and monitoring options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, desktop or laptop computer, Bluetooth (with optional VE.Bus Smart dongle), battery controller, Multi Control digital control panel.


    Remote configuration and supervision


    Install a Color Control GX or other GX product for Internet connection.
    Operating data can be stored and displayed on our free VRM (Victron Remote Management) website.
    If systems are connected via Ethernet, they can be accessed and their configuration modified.


    Standard marine, mobile or off-grid application


    Loads that need to be switched off when AC input power is not available can be connected to a second output (not switched off). These loads will be taken into account by the
    PowerControl and PowerAssist functions to limit the AC input current to a safe value if AC power is available.


    Grid-parallel topology with MPPT solar charge controller


    The MultiPlus-II will use data from the AC current sensor (to be ordered separately) or from the power meter to optimize self-consumption and, if necessary, avoid feeding energy back into the grid. In the event of a power failure, the MultiPlusII will continue to supply critical loads.


    Features

    MultiPlus-II12/3000/120-32 - 24/3000/70-32 - 48/3000/35-3224/5000/120-50 - 48/5000/70-5048/8000/110-
    100
    48/10000/140 -100
    PowerControl / PowerAssistYes
    Transfer switch32 A50A100A
    Maximum AC input current32 A50A100A
    CONVERTER
    DC supply voltage range12V - 9.5-17 V 24 V - 19-33 V 48 V - 38-66 V
    OutputOutput voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0.1% (1)
    Continuous output power at 25°C (3)3000 VA5000 VAVA10000 VA
    Continuous output power at 25°C2400 W4000 W6400 WW
    Continuous output power at 40°C2200 W3700 W5500 WW
    Continuous output power at 65 °C1700 W3000 W4000 W6000 W
    Assumed max. return power3000 VA5000 VAVA10000 VA
    Peak power5500 WW15000 W18000 W
    Maximum efficiency93 % / 94 % / 95 %96 %95 %96 %
    No-load power consumption13 / 13 / 11 W18 W29 W38 W
    No-load power consumption in AES mode/ 9 / 7 W12 W19 W27 W
    Zero charge power in Search mode/ 3 / 2 WWWW
    CHARGER
    AC inputSupply voltage range: 187-265 VAC Input frequency: 45 - 65 Hz
    Absorption charging voltage14.4 / 28.8 / 57.6 V
    Float charge voltage13.8 / 27.6 / 55.2 V
    Storage mode13.2 / 26.4 / 52.8 V
    Maximum battery charging current120 /70 / 35 A120 / 70 A110 A140 A
    Battery temperature sensorYes
    GENERAL
    Auxiliary outputYes (32 A)Yes (50 A)
    External AC current sensor (optional)50 A100 A
    Programmable relayYes
    Protection- g
    VE.Bus communication portFor parallel (not compatible with 8 and 10 k models) or three-phase operation, remote control and system integration
    Universal com. portYes, 2x
    Remote on/offYes
    Operating temperature rangeto +65°C (fan cooled)
    Humidity (non-condensing)max. 95
    CASING
    Material and colorSteel, blue RAL 5012
    Degree of protectionIP22
    Battery connectionM8 nutsM8 bolts (2 positive and 2 negative connections)
    Connection 230 VACScrew terminals 13 mm2 (6 AWG)Bolts M6
    Weight19 kg30 kg42 kg49 kg
    Dimensions (H x W x D) mm546 x 275 x 147 499 x 268 x 141 499 x 268 x 141x 328 x 240 560 x 320 x 141642 x 363 x 206x 363 x 206
    STANDARDS
    SafetyEN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2
    Emission, ImmunityEN 55014-1, EN 55014-2 EN-IEC 61000-3-2, EN-IEC 61000-3-3 IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
    PMP242505010

    Specific References

    New