5
    MPPT controller Victron SmartSolar 100/30 - 100/50 12/24V

    MPPT controller Victron SmartSolar 100/30 - 100/50 12/24V

    €165.77
    Tax included
    10058
    0712971136229

    Especially under cloudy skies, when light intensity is constantly changing, an ultra-fast MPPT controller will improve energy harvesting by up to 30% compared with PWM charge controllers, and by up to 10% compared with slower MPPT controllers.

    Charge controller Victron SmartSolar Models: SmartSolar MPPT 12/24V 100/30

    MPPT controller Victron...

    €165.77

    Victron

    Ultra-fast maximum power point tracking (MPPT).

    Especially under cloudy skies, when light intensity is constantly changing, an ultra-fast MPPT controller will improve energy harvesting by up to 30% compared with PWM (pulse-width modulation) charge controllers, and by up to 10% compared with slower MPPT controllers.


    Advanced maximum power point detection in shaded conditions

    Under shadowing conditions, two or more maximum power points may be present on the voltage-power curve. Conventional MPPTs tend to lock on to a local MPP which
    not necessarily the optimum MPP. SmartSolar's innovative algorithm will always maximize energy recovery by locking on to the optimal MPP.


    Outstanding conversion efficiency

    No fan. Maximum efficiency in excess of 98%.


    PV voltage up to 100 V

    The charge controller can charge a battery of lower nominal voltage from a field of PV panels of higher nominal voltage. The controller will automatically adapt to a nominal battery voltage of 12 or 24 V.


    Automatic battery voltage recognition

    The controller will automatically adjust to a 12 or 24 V system only once. If a different system voltage is required at a later stage, it will have to be changed manually, for example using the Bluetooth application.


    Adaptive charging in three steps

    The controller is configured for a three-stage charging process: Bulk - Absorption - Float.

    Bulk
    During this stage, the controller delivers as much current as possible to rapidly recharge the batteries.

    Absorption
    When the battery voltage reaches the absorption voltage parameters, the controller switches to constant voltage mode. During shallow battery discharges, the absorption charge time is limited to prevent overcharging. After a deep discharge, the absorption time is automatically increased to ensure the battery is fully recharged. The absorption period also ends when the charging current falls below 2A.

    Float
    During this stage, Float voltage is applied to the battery to keep it in a fully charged state. When the battery voltage drops below the Float voltage for at least 1 minute, a new charge cycle is triggered.


    Flexible charging algorithm

    Fully programmable charging algorithm (see the Software section of our website) and eight pre-programmed algorithms selectable with a rotary switch (see manual for details).


    Extended electronic protection

    Protection against overheating and power reduction in case of high temperature.


    Internal temperature sensor

    Compensates Float and Absorption charge voltages as a function of temperature.


    VE.Direct

    For wired data connection to a Color Control panel, PC or other devices.


    Remote on/off

    For connection to a VE.BUS BMS, for example.


    Programmable relay

    Can be programmed (e.g. with a Smartphone) to trigger an alarm, or other events.

    martSolar charge controllerMPPT 100/30MPPT 100/50
    Battery voltageAutomatic selection 12/24 V
    Maximum battery current30A50A
    PV power rating,
    12 V 1a, b)440W700W
    PV rated power, 24 V 1a, b)
    1400W
    Maximum PV open circuit voltage100V
    Max.
    PV short-circuit current 2)35A60A
    Peak efficiency98%
    Self-consumption10 mA
    "Absorption" charging voltageDefault configuration: 14.4 V / 28.8 V / 57.6 V (adjustable)
    "Equalization" charging voltage 3)Default configuration:
    16.2 V / 28.8 V / 64.8 V (adjustable)
    "Float" charging voltageDefault configuration: 13.8 V / 27.6 V / 55.2 V (adjustable)
    Charging algorithmAdaptive multi-step algorithm (eight pre-programmed algorithms) or user-defined algorithm
    Temperature compensation
    mV / °C resp.
    -32 mV / °C
    ProtectionBattery polarity reversal (fuse, not accessible to user)
    Output short-circuit
    Overheating
    Operating temperature
    to +60°C (rated output power up to 40°C)
    Humidity95 %,
    non-condensing
    Maximum altitude5000 m (full rated output up to 2000 m)
    Environmental conditionsIndoor Type 1, without air conditioning
    Pollution levelPD3
    Data communication port and remote on/offVE.Direct
    CASING
    ColorBlue (RAL 5012)
    Power terminals13 mm² / AWG6
    Degree of
    IP43 (electronic components)
    IP 22 (connection area)
    Weight
    ,25 kg
    Dimensions (h x w x d)130 x 186 x 70 mm
    NORMES
    SafetyEN/IEC 62109-1
    ) If higher PV power is connected, the controller will limit the input power

    1b) The PV voltage must exceed Vbat + 5 V for the controller to switch on.
    Then, the minimum PV voltage is Vbat + 1 V
    2) A PV array with a higher short-circuit current may damage the controller.
    10058

    Data sheet

    Charging power
    30A
    50A

    Specific References

    New

    Download