With its production and consumption measurement options, the Enphase Envoy-S is an intelligent platform for comprehensive management of your energy production.
6 item(s) left in Stock!
The Enphase Envoy-S Metered™ communication gateway transmits photovoltaic production and energy consumption data to Enlighten™, Enphase's monitoring and analysis software for fully remote maintenance and management of an Enphase system.
With production and consumption measurement options, the Envoy-S is an intelligent platform for comprehensive energy management and works in conjunction with the Enphase™ AC battery.
Intelligence
- Offers web-based control and monitoring
- Two-way communications for remote upgrading
Simplicity
- Simple system configuration with the Installer Toolkit mobile app
- Flexible network connection: Wi-Fi, Ethernet or cellular
Reliability
- Designed for indoor or outdoor installation, in an enclosure
- 5-year warranty
Features
MODEL REFERENCE |
ENV-S-WM-230 (three-phase) | Enphase Envoy-S communication gateway offering integrated measurement of photovoltaic production and energy consumption |
C
ONFIGURATION REQUIRED FOR POWER SUPPLY |
Wired | 230 V AC or 400Y/230 V AC, 50 Hz Max. 20 A overcurrent protection. |
required |
CAPACITY |
Number of devices detected | Up to 600 microinverters |
MECHANICAL |
Dimensions (W x H x D) | 213 x 126 x 45 mm |
Weight |
,5 kg |
Ambient temperature range |
40 °C to 65 °C |
40 °C to 46 °C if installed in an enclosure |
Environmental classification | IP30 for indoor installation or in an IP54 (or higher) enclosure |
A
ltitude |
,000 meters max. |
USB ports | Two USB 2.0 ports, auto-detect, auto-negotiate |
INTERNET CONNECTION OPTIONS |
Integrated Wi-Fi | 802.11b/g/n (2.4 GHz, 5 GHz) |
Ethernet | Optional, 802. |
3
, Ethernet Cat5E (or Cat 6) UTP cable (not included) |
Mobile | Optional, CELLMODEM-02 (not included) |
CONFORMITY |
Conformity | IEC/EN 61010-1:2010, EN50065-1, EN61000-4-5, EN61000-6-1, EN61000-6-2 |