0
    Victron Battery protect BP 48-100

    Victron Battery protect BP 48-100

    €177.87
    Tax included
    VIC0041
    0712971132771
    BatteryProtect protects the solar battery by disconnecting it from non-essential loads before it is completely discharged (which would damage it) or before it has enough power left to start the motor.
    With 7-segment display: easy to configure

    BatteryProtect: BP 48-100

    Victron Battery protect BP...

    €177.87

    "Protect your batteries: Battery Protect from Victron disconnects non-essential loads automatically."

    Victron Energy's BatteryProtect automatically disconnects non-essential consumers from the battery before it is completely discharged (and damaged), or before it is too discharged to start the engine.


    Description

    Victron batteryprotect 48-100

    Easy programming

    BatteryProtect can be configured to activate/deactivate at different voltage levels. The 7-segment display indicates which configuration has been chosen.


    Special configuration for lithium-ion batteries

    In this mode, the BatteryProtect can be controlled by the VE-Bus BMS.


    Very low energy consumption

    This is an important feature for lithium-ion batteries, especially after a low-voltage stop.

    Please consult our lithium-ion battery data sheet and the VE.Bus BMS manual for more information.


    Protection against overvoltage and combustion

    > To protect sensitive equipment from overvoltage, the load is automatically disconnected when DC voltage exceeds 16 V or 32 V.

    > To protect devices against combustion: no relays, but MOSFET transistors, so there's no sparking.


    Delayed alarm output

    The alarm output is activated if the battery voltage drops below the preset disconnection level for more than 12 seconds. Starting the motor will therefore not activate the alarm. The alarm output is a short-circuit-proof open-collector output connected to the rail (negative), maximum current 50 mA. The alarm output is generally used to activate a buzzer, LED or relay.


    Load disconnection and reconnection times

    The load will be disconnected 90 seconds after the alarm is activated. If the battery voltage rises again to the connection threshold during this period (when the motor has been started, for example), the load will not be disconnected.

    The load will be reconnected 30 seconds after the battery voltage exceeds the preset load reconnection voltage.


    Technical data

    BatteryProtect

    BP-48-100

    Maximum continuous charging current

    100 A

    Peak power250 A
    Operating voltage range24-64 A
    Current consumptionIf switched on: 2mA If off or if switched off in case of low voltage:
    0.8 mA
    Alarm output delay12 seconds
    Maximum load on alarm output50 mA (short-circuit protection)
    Time to load disconnection30 seconds
    thresholdsDisable:
    42V On: 48 V
    Operating temperature rangeFull load:-40°C to +40°C (up to 60% of rated load at 50°C
    Weight
    .8 kg
    Dimensions (H x W x D)62 x 123 x 120 mm
    BatteryProtectBP-48-100

    Battery protect de victron

    (Datasheet download)

    VIC0041

    Specific References

    New

    Download

    Datasheet Victron BP 48-100 FR

    Download (189.38KB)

    Datasheet Victron BP 48-100 EN

    Download (215.58KB)

    Manual Victron BP 48-100 EN-FR

    Download (512.56KB)