Converter Victron Phoenix VE Direct 12/24/48V - 375VA
Phoenix VE.Direct 12/24/48 375VA converter.
Developed for professional use, the Phoenix range of converters is perfectly suited to a wide variety of applications.
Phoenix converter - VE.Direct
Converters enable you to power household equipment - requiring a 230 V power source - using "leisure" or "automotive" batteries with a voltage of 12 V, 24 V or 48 V.
VE.Direct communication port
The VE.Direct port can be connected to:
- A computer (VE.Direct-USB interface cable required).
- Apple and Android smartphones, tablets, macbooks and other devices (a Bluetooth Smart dongle communicating with VE.Direct is required).
Fully configurable:
- Reset levels and alarm triggering in the event of low battery voltage
- Restart levels and cut-off in the event of low battery voltage
- Dynamic cut-off: load-dependent cut-off level
- Output voltage 210 - 245 V
- Output frequency 50 Hz or 60 Hz
- ECO mode detection level and ECO mode on/off.
Monitoring:
- Input and output voltage, % load and alarms
Proven reliability
The full-bridge topology with toroidal transformer has proven its reliability for years.
The converters are protected against short-circuits and overheating, whether in the event of overload or high ambient temperature.
High starting power
Necessary for starting loads such as power converters for LED or halogen bulbs, or power tools.
ECO mode
In ECO mode, the converter will pause if the load drops below a pre-set value (minimum load: 15 W). Once paused, the inverter will switch on for a short period of time (adjustable; default: every 2.5 seconds). If the load exceeds a pre-set level, the inverter will remain on.
Remote on/off.
A remote on/off switch can be connected to a two-pole connector or between the positive battery pole and the left contact of the two-pole connector.
Diagnostic LED
Please refer to the manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low-power converters, we recommend the use of our Filax automatic transfer switch. The Filax benefits from a very fast transfer time (less than 20 milliseconds), so that computers and other electronic equipment can continue to operate without interruption.
VictronConnect
VictronConnect lets you get live status information and configure your Victron products using the built-in Bluetooth device or a Bluetooth Smart dongle connected to VE.Direct.
Features
Victron Phoenix | 12V / 375 VA | 24V / 375 VA | 48V / 375 VA |
Continuous power at 25°C | 375 VA | ||
Peak power | 700 W | ||
Frequency / AC output voltage (adjustable) | 230 VAC or 120 VAC +/- 3% 50 Hz or 60 Hz +/- 0.1 | ||
Supply voltage range | .2 - 17 / 18.4 - 34.0 / 36.8 - 62.0 V | ||
Low DC current shutdown (adjustable) | .3 / 18.6 / 37.2 V | ||
Dynamic (load-dependent) DC low-current shutdown (fully adjustable) | Dynamic shutdown, see https://www.victronenergy.com/live/ve.direct : phoenix-inverters-dynamic-cutoff | ||
Low DC alarm and restart (adjustable) | 10.9 / 21.8 / 43.6 V | ||
Charged battery detection (adjustable) | 14.0 / 28.0 / 56.0 V | ||
Maximum efficiency | 89 / 89 / 90 | ||
No-load consumption | .6 / 6.1 / 8.5 W | ||
Default no-load consumption in ECO mode (default retry interval: 2.5 s, adjustable) | .9 / 1.4 / 2.6 W | ||
Start/stop power parameter in ECO mode | Adjustable | ||
Operating temperature range | to +65 °C (fan cooled) (1.25% reduction per °C above 25 °C) | ||
Humidity (non-condensing) | Max. 95% | ||
CASING | |||
Material and color | Steel frame and plastic cover (Blue RAL 5012) | ||
Battery connection | Screw terminals | ||
Maximum cable cross-section | 10 mm² / AWG8 | ||
Standard AC sockets | 230 V: Schuko (CEE 7/4), IEC-320 (plug included) | ||
Degree of protection | IP21 | ||
Weight | .0 kg | ||
Dimensions (H x W x D) | 86 x 165 x 260 mm | ||
ACCESSORIES | |||
Remote on/off switch | Yes | ||
Automatic transfer switch | Filax | ||
STANDARDS | |||
Safety | EN-IEC 60335-1 / EN-IEC 62109-1 | ||
EMC | EN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-2 / IEC 61000-6-3 | ||
Automotive directive | ECE R10-4 |