The high-performance Antaris 7.5kW wind turbine is designed in Germany.
It's perfect for a home installation
MODERN - FLEXIBLE - POWERFUL
Max. 20 kW wind turbine load (SW-10)
Pairing the three-phase network with 10 kW (SW-10)
Flexible and intelligent management of clean power, heating, battery and discharge charges through 4 separate CC energy outlets
Energy counter for power and heating
Control of reactive power
Battery buffer interface - optional
PROFITABLE - SURE
Built-in control functions for a wind turbine Intelligent and finely resolute control of the characteristic curve for optimal wind use
Characteristic curve freely selectable depending on voltage or speed
Many monitoring functions, such as wind speed or speed
Switch to shut down KWEA with other safety features
Compact
Direct connection of the particle generator without additional equipment
Wide range of input voltage for particle generators
Compact design of the case with a separate aperture connection area
Passive convection cooling on a wide range of performance
Integrated network/system protection (NA protection according to VDE AR-N 4105)
Communicative
Built-in graphic display
Built-in web server
Practical PC Smart!wind Explorer use and set-up interface
APPLICATION AREAS
Small wind turbines
Small hydroelectric power plants
Mini-cogeneration
General data | SW-7.5 |
Size | 656 x 472 x 234 mm |
Weight | 42 kg |
Protective class | IP54 |
Cooling | Passive air/fan controlled according to demand |
How it works in the temperature range | -25 degrees Celsius ... -40 degrees Fahrenheit - automatic decommissioning |
Global efficiency | No more than 94%. |
Clean consumption | 18 W - Waiting |
83 W - Active offer | |
Entry generator side | |
Generator type | excited constantly / 3 phases |
Generator-side lifter | B6 |
60...500 VLL | |
310 ... 500 VLL - for a full power of 10 kW | |
600 VLL - maximum | |
Entry voltage range (driver-driver) | 20 A - face value |
Entry current (nominal value) | 40 A - max. 5 s |
Entry power | 15 kW - face value |
Entry current (nominal value) | 30 kW - max. 5 s |
Maximum value limited by load resistance | 0 Hz ... 150 Hz |
Frequency of entry | Isolation control |
Monitoring generators | Temperature control |
Speed control | |
Exit sector side | |
Inverter sector side | IGBT B6 |
Number of phases | 3 |
Output power (nominal value) | 7.5 kW |
Exit tension | 400 VLL - face value |
318 ... 460 VLL - eligible reach | |
Outfed current (nominal value) | 0 ... 11 A |
Exit frequency | 0 Hz ... 150 Hz |
Separation concept | without transformer - no galvanic insulation |
Power factor - cos | 3% |
Power factor - cos | regulated to 1 - regulation according to VDE AR-N 4105 |
Resistance to short circuits | Current control |
Network/system protection - ENS | VDE AR-N 4105 |
![]() | ![]() |